-Language-
How To Set The Timeout Prompt For FC-198E?
2016-12-22 16:58
Details of the problem:

Hello, we are purchasing your company's FC-198E machine and install in our warehouse door. It is very frequent that our warehouse deliver goods in and out, so the door open all the time,sometimes they are too busy to lock the door. Is there any way to remind the employees to close the door.

Expert answer:

Hello,FC-198E support this function. As long as you turn on this function,you open the door and did not close it on time. It will has the "DI DI DI" voice to remind you.

The operation way:

1. Enter administrate state: (* + administration password + #)

2. Modify open time out prompt(TYPE 6 3 + # + 3 DIGIT OPEN TOMEOUT + #)

Note:if entering 00,this function will be turned off.the unit of measurement is second,and the maximum time can be set to 999 seconds.