When installing and debugging MC-5812T, it was found that the electric bolt lock did not have 12V voltage during the test
Details of the problem:

Hello, when installing and debugging MC-5812T, what is the reason why the electric bolt lock has no 12V voltage during the test, and how to solve it?

Expert answer:

Hello, there is no voltage on the electric bolt lock, please check whether the wiring is missing or connected incorrectly. The +12V of the power supply is connected to the COM port of the controller, the positive pole of the electric bolt lock is connected to the NC of the controller, and the negative pole of the electric bolt lock is connected to the GND of the power supply.

QQ QQ TEL
Please select the customer service
广州店 总统店 深圳店 重庆店 海南店 北京店 石英仙 郑翠妃 范彩霏 朱海松 张观进 邓才钦 技术支持01 技术支持02 技术支持03 二次开发支持 国际销售部 投诉与建议