FC-S02 Access Controller Wiring Diagram
Details of the problem:

Hi, we have bought your company's FC-S02E access controller,but the user manual missed, can you provide us the wiring diagram?

Expert answer:

Thanks for your support. This is our wiring diagram, please do a reference:

FC-S02 Access Controller Wiring Diagram


Connection Port Performance:

1. +12V: Working power supply anode, input range: DC9-13.8V.

2. GND: Working power supply cathode, signal common ground.

3. NO: Relay normal open point, current load capacity DC3A / 30V.

4. COM: Relay common point, current load capacity DC3A / 30V.

5. NC: Relay normal close point, current load capacity DC3A / 30V.

6. OPEN: Exit Button, low level unlock.

7. DOOR: Door status switch, connected to magnet,low level represents door shut.

8. ALM: Alarm output port, low level there is alarm, current load 100ma.

9. BELL: Connected to doorbell.


If you still don’t understand, you can ask us at any time and we will answer you in time.

QQ QQ TEL
Please select the customer service
广州店 总统店 深圳店 重庆店 海南店 北京店 石英仙 郑翠妃 范彩霏 朱海松 张观进 邓才钦 技术支持01 技术支持02 技术支持03 二次开发支持 国际销售部 投诉与建议