How To Modify Open Delay Time For FC - 198E machine?
Details of the problem:

Hello,we buy FC-198E machine in your company and installed it. But when we debug this machine and find that the electric lock close very quickly.

We did not contact too much for access control. So, we want to know how to set the Electric RFID Lock close slowly.

Expert answer:

FC-198E has this function, you can set the electric time you like. The operation way as below.

1. Enter administrate state: (* + administration password + #)

2. Modify open delay time:(TYPE 6 6 + # + 3 DIGIT OPEN DELAY TIME + #)

NOTE: if entering 005, the system default to 3 seconds, the longest delay time can be set to 255 seconds.

YOU ALSO CAN DELAY TIME IN ACCESS CONTROL POWER BOX.THE PICTURE SHOW AS BELOW.


QQ QQ TEL
Please select the customer service
广州店 总统店 深圳店 重庆店 海南店 北京店 石英仙 郑翠妃 范彩霏 朱海松 张观进 邓才钦 技术支持01 技术支持02 技术支持03 二次开发支持 国际销售部 投诉与建议